کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
874192 910328 2008 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
پیش نمایش صفحه اول مقاله
Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction
چکیده انگلیسی

Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage–bone plugs were dissected and tested in a simple shear sandwich configuration under a compressive strain of 10%. Sinusoidal shear strain (frequency range: 0.01–10 Hz) was applied in the medio-lateral or antero-posterior direction with an amplitude of 1.0%, 2.0%, and 3.0%. The magnitudes of the dynamic shear moduli, as calculated from the resulting shear stress, were found to increase with applied frequency and the shear strain amplitude. The values of ∣G*∣, G′ and G″ for a medio-laterally applied shear were about 20–33% of those in the antero-posterior shear, although the loss tangent (elasticity/viscosity ratio) was almost the same. In conclusion, the present results clearly show the direction-dependent characteristic of the mandibular condylar cartilage in dynamic shear.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Biomechanics - Volume 41, Issue 5, 2008, Pages 1119–1123
نویسندگان
, , , , , , , , ,