Movement variability cannot be determined reliably from no-marker conditions
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
پیش نمایش صفحه اول مقاله
Movement variability cannot be determined reliably from no-marker conditions
چکیده انگلیسی

We sought to quantify the proportion of total variability due to movement variability in digitizing marker and no-marker conditions in treadmill running. Manually digitized markers gave variabilities in joint angles within 0.4° of those from auto-tracking. Marker conditions allowed reliable estimation of movement variability by an experienced operator; the contribution of movement variability to total variability, expressed by omega-squared, had averages across the four operators of 97% for the knee angle and 93% for the hip. The no-marker condition did not allow reliable estimation of movement variability—the above figures fell, respectively, to 72% and 48%—and cannot be recommended. The group design in the marker condition produced omega-squared values of 97% knee and 91% hip, showing excellent objectivity (inter-operator reliability). However, without markers, these values fell to 47% and 15%, respectively, indicating that movement variability cannot be assessed objectively in no-marker conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Biomechanics - Volume 39, Issue 16, 2006, Pages 3076–3079
نویسندگان
, , ,