عنوان انگلیسی مقاله ISI
2Â m heat pipe-cryogenic targets for COSY-TOF experiment
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
ابزار دقیق
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
A liquid hydrogen/deuterium target is used in COSY external experiments. For the TOF and WASA applications at COSY, a 2.0Â m long, 7Â mm diameter heat pipe (HP) has been developed and tested under filling conditions of 9.45Â l at 228Â mbar with the four gases H2, D2, N2 and CH4. The cooling down times are 107, 200, 54 and 38Â mins, respectively, from 300Â K until working conditions have been achieved. The target liquid is produced at a cooled condenser and guided through a central tube assisted by gravitation into the target cell. The characteristics at steady-state operating conditions were measured for H2, N2 and CH4 as the working fluids. The effect of the operating temperature and the heat loads on the effective thermal conductivity and the liquid mass in the heat pipe was investigated.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 551, Issues 2â3, 11 October 2005, Pages 236-244
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 551, Issues 2â3, 11 October 2005, Pages 236-244
نویسندگان
M. Abdel-Bary, S. Abdel-Samad, K. Kilian,