کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9845105 1526507 2005 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Correlation of beam electron and LED signal losses under irradiation and long-term recovery of lead tungstate crystals
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Correlation of beam electron and LED signal losses under irradiation and long-term recovery of lead tungstate crystals
چکیده انگلیسی
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystal recovery from such damage.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 550, Issue 3, 21 September 2005, Pages 543-550
نویسندگان
, , , , , , , , , , , , , , , , ,