کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9845732 1526520 2005 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Radiation sensitivity of GSO and LSO scintillation detectors
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Radiation sensitivity of GSO and LSO scintillation detectors
چکیده انگلیسی
Radiation resistance of 4×4×30 mm3 GSO and LSO imaging scintillation detectors has been studied for low-energy gamma-ray doses of 104 Gy (106 rad) and 105 Gy (107 rad). Radiation hardness was determined by the measurement of optical transmission through GSO and LSO scintillation crystals before and after irradiations with 60Co gamma-rays. The results have been analysed in terms of the radiation-induced absorption coefficients and compared with radiation sensitivity measurements of small BGO scintillation crystals. The recovery time of irradiated small GSO and LSO crystals has also been determined.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 539, Issues 1–2, 21 February 2005, Pages 132-136
نویسندگان
, ,