In Norway there is a growing concern that electricity production and transmission may not meet the demand in peak-load situations. It is therefore important to evaluate the potential of different demand-side measures that may contribute to reduce peak load. This paper analyses data from an experiment where residential water heaters were automatically disconnected during peak periods of the day. A model of hourly electricity consumption is used to evaluate the effects on the load of the disconnections. The results indicate an average consumption reduction per household of approximately 0.5 kWh/h during disconnection, and an additional average increase in consumption the following hour, due to the payback effect, that may reach up to 0.28 kWh/h per household.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Policy - Volume 37, Issue 9, September 2009, Pages 3502–3512