Accuracy of emergency medicine ultrasound in the evaluation of abdominal aortic aneurysm
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
پیش نمایش صفحه اول مقاله
Accuracy of emergency medicine ultrasound in the evaluation of abdominal aortic aneurysm
چکیده انگلیسی
This study assesses the accuracy of Emergency Medicine (EM) residents in detecting the size and presence of abdominal aortic aneurysms (AAAs) using EM ultrasound (EUS) compared to radiology measurement (RAD) by computed tomography (CT) scan, magnetic resonance imaging (MRI), angiography, or operative findings. There were 238 aortic EUS performed from 1999-2000; 36 were positive for AAA. The EUS finding of “AAA” had a sensitivity of 0.94 (0.86-1.0 95% confidence interval [CI]) and specificity of 1 (0.98-1.0 95% CI). Mean aortic diameter among patients with AAA identified by EUS was 5.43 ± 1.95 cm and by RAD was 5.35 ± 1.83 cm. The mean absolute difference between EUS and RAD diameters was 4.4 mm (95% CI 3.7-5.5 mm). Regression of EUS on RAD diameters is strongly correlated, with R2 = 0.92. EM residents with appropriate training can accurately determine the presence of AAA as well as the maximal aortic diameter.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Emergency Medicine - Volume 29, Issue 4, November 2005, Pages 455-460