کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10081693 1604092 2005 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Prospective Evaluation of Total Hip Arthroplasty With a Cementless, Anatomically Designed, Porous-Coated Femoral Implant: Mean 11-Year Follow-up
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Prospective Evaluation of Total Hip Arthroplasty With a Cementless, Anatomically Designed, Porous-Coated Femoral Implant: Mean 11-Year Follow-up
چکیده انگلیسی
The performance of an anatomically designed femoral implant with porous titanium mesh coating was assessed in patients undergoing total hip arthroplasty. The stem, with built-in 12° anteversion, was implanted in neutral position relative to the long axis of the femur through a cementless press-fit application. The only requirement was the presence of sufficient thickness within the cortical bone of the femoral metaphysis to support the stem. Ninety-one evaluable patients were followed up for a minimum of 10 years. Patients tolerated weight-bearing activity within 24 hours after surgery. Only 1 femoral component required revision because of loosening. Most patients showed uniform bony ingrowth. Quality of life was markedly improved. The anatomically designed, porous-coated implant provides robust performance which has general utility in a wide range of patients.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 20, Issue 6, September 2005, Pages 709-716
نویسندگان
, , ,