کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10568079 973367 2005 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Integral condition monitor for valve-regulated lead-acid batteries
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Integral condition monitor for valve-regulated lead-acid batteries
چکیده انگلیسی
A battery condition monitor is described that can be integrally mounted within a valve-regulated lead-acid (VRLA) battery. The device continuously monitors battery voltage, temperature and elapsed time. These parameters are processed to identify the status of the battery in terms of charge, discharge or resting modes. The state-of-charge is determined based on voltage and temperature measurements taken during resting periods, when the battery components adequately approach equilibrium conditions. The resulting whole-life record, built from the integration of instantaneous readings, is compared with a simple life model, based on the number and the depth of the discharges performed. Laboratory tests and ongoing field trials indicate that this approach can provide cost-effective and convenient monitoring of VRLA batteries in specific types of application.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Power Sources - Volume 144, Issue 2, 15 June 2005, Pages 513-520
نویسندگان
,