کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
11000005 1421095 2018 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Motion analysis and system response of fertilizer feed apparatus for paddy Variable-Rate fertilizer spreader
ترجمه فارسی عنوان
تجزیه و تحلیل حرکت و پاسخ سیستم از دستگاه تغذیه کود برای پلت فرم باروری کود متغیر
کلمات کلیدی
محرک خوراک، کالیبراسیون لاغر، پاسخ سیستم، تاخیر زمانی، کود متغیر،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزارهای علوم کامپیوتر
چکیده انگلیسی
Precision agriculture and variable-rate technology have gained increasing public interest. To improve the rapid response ability of the control system of a variable-rate fertilization and reduce the errors corresponding to the feed fertilizer system in a centrifugal variable-rate spreader, three devices that could adjust the application rate using different actuators were developed; these involved the gear and rack structure A, electric handspike structure B, and screw slider structure C. Mechanism motion analysis models were established based on vector equations, the response analysis of system delay was performed according to the model of lag fertilization, and subsequently, performance tests were executed to calibrate the lag distance of falling fertilizer, as well as the response time of actuators and the error of feed fertilization flow. The test results indicated that for actuators A, B, and C, the average lag distance of falling fertilization was in the order LA > LC > LB, with the respective values being 3.56, 2.72, and 1.85 m; the corresponding lag correction times were 1.99, 1.74, and 1.48 s, respectively. A positive proportional relation was noted between the application increment and response time of apparatus execution, and TBi > TCi > TAi (i denotes the corresponding feed fertilization flow). Furthermore, the error of fertilization flow first decreased and then increased with the increasing application rate; the extremum appeared between 250g/s and 380g/s, and γBi > γAi > γCi. The feed fertilizer with structure C was optimized and integrated field validation tests, and incorporating the corresponding correction time of lagging response Tlag = 1.74 s into the control system, the mean error of variable-rate fertilization system was determined as 9.67%, and the average lag distance of fertilization was 0.37 m. This indicated that the control system of variable-rate fertilization with correction response time alleviated the problem of lag falling fertilizing, improved the response speed of variable-rate fertilization for rice, and helped achieved better fertilization accuracy.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computers and Electronics in Agriculture - Volume 153, October 2018, Pages 239-247
نویسندگان
, , , , ,