کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1189210 963507 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A non-plasticized chitosan based solid state electrode for flow injection analysis of glutamate in food samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
A non-plasticized chitosan based solid state electrode for flow injection analysis of glutamate in food samples
چکیده انگلیسی

This report describes the development of solid state glutamate sensor based on chitosan. The electrode has linearity range of 0.01–1 mM glutamate with detection limit of 0.008 mM. The presence of other conventional food additives at physiological level does not interfere. The interfering effect is, however, minimized through prior dilution of the sample. Recovery values of 88.9–99.2% are obtained throughout. The proposed electrode has been applied in flow injection analysis (FIA) glutamate in food samples. In the validation experiment, the proposed electrode is found to be comparable with the standard method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Food Chemistry - Volume 112, Issue 3, 1 February 2009, Pages 756–759