کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1229077 1495231 2015 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Five different spectrophotometric methods for determination of Amprolium hydrochloride and Ethopabate binary mixture
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Five different spectrophotometric methods for determination of Amprolium hydrochloride and Ethopabate binary mixture
چکیده انگلیسی


• These methods are sensitive and resolve binary mixture with overlapping spectra.
• The good recovery and accuracy make them applicable in QC laboratories.
• The proposed methods can be used in QC without the difficulties of HPLC.
• The proposed methods were validated according to ICH guidelines.
• The proposed methods have been applied successfully on veterinary formulation.

Five simple, specific, accurate and precise UV-spectrophotometric methods are adopted for the simultaneous determination of Amprolium hydrochloride (AMP) and Ethopabate (ETH), a binary mixture with overlapping spectra, without preliminary separation. The first method is first derivative of the ratio spectra (1DD) for determination of AMP and ETH at 234.7 nm and 306.8 nm respectively with mean percentage recoveries 99.76 ± 0.907 and 100.29 ± 0.842 respectively. The second method is the mean centering of the ratio spectra for determination of AMP and ETH at 238.8 nm and 313 nm respectively with mean percentage recoveries 100.26 ± 1.018 and 99.94 ± 1.286 respectively. The third method is based on dual wavelength selection for determination of AMP and ETH at 235.3 nm & 308 nm and 244 nm & 268.4 nm respectively with mean percentage recoveries 99.30 ± 1.097 and 100.03 ± 1.065 respectively. The fourth method is ratio difference method for determination of AMP and ETH at 239 nm & 310 nm and 239 nm & 313 nm respectively with mean percentage recoveries 99.27 ± 0.892 and 100.40 ± 1.814 respectively. The fifth one is area under the curve (AUC) method where the areas between 235.6–243 nm and 268.3–275 nm are selected for determination of AMP and ETH with mean percentage recoveries 100.35 ± 1.031 and 100.39 ± 0.956 respectively. These methods are tested by analyzing synthetic mixtures of the two drugs and they are applied to their pharmaceutical veterinary preparation. Methods are validated according to the ICH guidelines and accuracy, precision and repeatability are found to be within the acceptable limit.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 138, 5 March 2015, Pages 395–405
نویسندگان
, , ,