کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1230550 1495240 2014 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development and validation of simultaneous spectrophotometric and TLC-spectrodensitometric methods for determination of beclomethasone dipropionate and salbutamol in combined dosage form
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Development and validation of simultaneous spectrophotometric and TLC-spectrodensitometric methods for determination of beclomethasone dipropionate and salbutamol in combined dosage form
چکیده انگلیسی


• Simultaneous determination of beclomethasone dipropionate (BEC) and salbutamol (SAL).
• Spectrophotometric methods include dual wavelength, ratio difference, and mean centering.
• Constant center method coupled with a novel method namely, spectrum subtraction.
• TLC-spectrodensitometric method was applied for separation and determination.
• Validated according to the ICH guidelines & compared to the official methods.

Spectrophotometric and TLC-spectrodensitometric methods were developed and validated for the simultaneous determination of beclomethasone dipropionate (BEC) and salbutamol (SAL). The spectrophotometric methods include dual wavelength, ratio difference, constant center coupled with a novel method namely, spectrum subtraction and mean centering with mean percentage recoveries and RSD 99.72 ± 1.07 and 99.70 ± 1.12, 100.25 ± 1.12 and 99.89 ± 1.12, 99.66 ± 1.85 and 99.19 ± 1.32, 100.74 ± 1.26 and 101.06 ± 0.90 for BEC and SAL respectively. The TLC-spectrodensitometric method was based on separation of both drugs on TLC aluminum plates of silica gel 60 F254, using benzene: methanol: triethylamine (10:1.5:0.5 v/v/v) as a mobile phase, followed by densitometric measurements of their bands at 230 nm. The mean percentage recoveries and RSD were 99.07 ± 1.25 and 101.35 ± 1.50 for BEC and SAL respectively. The proposed methods were validated according to ICH guidelines and were applied for the simultaneous analysis of the cited drugs in synthetic mixtures and pharmaceutical preparation. The methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of BEC and SAL in their pharmaceutical formulation with no need for prior separation. The results obtained were statistically compared to each other and to that of the reported HPLC method. The statistical comparison showed that there is no significant difference regarding both accuracy and precision.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 128, 15 July 2014, Pages 127–136
نویسندگان
, , , ,