کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1230997 1495258 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry
چکیده انگلیسی

A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene–divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5–12.0 μg L−1 of Tl(III) with relative standard deviation (RSD) of 1.40% (n = 10). The detection and quantification limits are 150 and 495 ng L−1 using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31 × 107 L mol−1 cm−1 and 0.00156 ng cm−2, respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene–divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5–12.0 μg L−1 of Tl(III) with relative standard deviation (RSD) of 1.40% (n = 10). The detection and quantification limits are 150 and 495 ng L−1 using 0.6 g of the exchanger. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.Figure optionsDownload as PowerPoint slideHighlights
► Sensitive procedure to determine trace amounts of Tl(III) by SPS has been developed.
► The procedure is based on fixation of Tl(III) as ion associate on anion-exchange resin.
► The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm.
► The procedure has been successfully applied to determine Tl(III) in real samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 110, June 2013, Pages 262–268
نویسندگان
, , ,