کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1231574 1495214 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Application and validation of superior spectrophotometric methods for simultaneous determination of ternary mixture used for hypertension management
ترجمه فارسی عنوان
کاربرد و اعتبار سنجی روشهای برتر اسپکتروفتومتری برای تعیین همزمان ترکیب مخلوطی که برای مدیریت فشار خون مورد استفاده قرار می گیرد
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Smart, simple and cost effective spectrophotometric methods were successively applied.
• The suggested methods can be used for simultaneous analysis of complex ternary mixtures without preliminary separation.
• Easier and more convenient analysis.
• Accurate and precise methods and could be easily applied in QC labs.
• Validated method as per ICH guidelines, appropriate parameters' values were obtained.

Telmisartan (TL), Hydrochlorothiazide (HZ) and Amlodipine besylate (AM) are co-formulated together for hypertension management. Three smart, specific and precise spectrophotometric methods were applied and validated for simultaneous determination of the three cited drugs. Method A is the ratio isoabsorptive point and ratio difference in subtracted spectra (RIDSS) which is based on dividing the ternary mixture of the studied drugs by the spectrum of AM to get the division spectrum, from which concentration of AM can be obtained by measuring the amplitude values in the plateau region at 360 nm. Then the amplitude value of the plateau region was subtracted from the division spectrum and HZ concentration was obtained by measuring the difference in amplitude values at 278.5 and 306 nm (corresponding to zero difference of TL) while the total concentration of HZ and TL in the mixture was measured at their isoabsorptive point in the division spectrum at 278.5 nm (Aiso). TL concentration is then obtained by subtraction. Method B; double divisor ratio spectra derivative spectrophotometry (RS-DS) and method C; mean centering of ratio spectra (MCR) spectrophotometric methods. The proposed methods did not require any initial separation steps prior the analysis of the three drugs. A comparative study was done between the three methods regarding their; simplicity, sensitivity and limitations. Specificity was investigated by analyzing the synthetic mixtures containing different ratios of the three studied drugs and their tablets dosage form. Statistical comparison of the obtained results with those found by the official methods was done, differences were non-significant in regard to accuracy and precision. The three methods were validated in accordance with ICH guidelines and can be used for quality control laboratories for TL, HZ and AM.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 155, 15 February 2016, Pages 103–110
نویسندگان
, ,