کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1232496 968792 2015 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Novel two wavelength spectrophotometric methods for simultaneous determination of binary mixtures with severely overlapping spectra
ترجمه فارسی عنوان
روشهای اسپکتروفتومتری دو روش طولی برای تعیین همزمان مخلوط های دوتایی با طیفهای شدید همپوشانی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Four novel spectrophotometric methods using two wavelengths.
• They can be used for analysis of binary mixtures with severely overlapped spectra.
• They do not need a special program and could be easily applied in QC labs.
• They have equal accuracy, precision compared to chromatographic methods.
• They were applied for analysis of the dosage form without inference of excipients.

This work presents the application of different spectrophotometric techniques based on two wavelengths for the determination of severely overlapped spectral components in a binary mixture without prior separation. Four novel spectrophotometric methods were developed namely: induced dual wavelength method (IDW), dual wavelength resolution technique (DWRT), advanced amplitude modulation method (AAM) and induced amplitude modulation method (IAM). The results of the novel methods were compared to that of three well-established methods which were: dual wavelength method (DW), Vierordt’s method (VD) and bivariate method (BV). The developed methods were applied for the analysis of the binary mixture of hydrocortisone acetate (HCA) and fusidic acid (FSA) formulated as topical cream accompanied by the determination of methyl paraben and propyl paraben present as preservatives. The specificity of the novel methods was investigated by analyzing laboratory prepared mixtures and the combined dosage form. The methods were validated as per ICH guidelines where accuracy, repeatability, inter-day precision and robustness were found to be within the acceptable limits. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed. No difference was observed between the obtained results when compared to the reported HPLC method, which proved that the developed methods could be alternative to HPLC techniques in quality control laboratories.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 136, Part C, 5 February 2015, Pages 1786–1796
نویسندگان
, , , ,