A robust cell voltage monitoring system for analysis and diagnosis of fuel cell or battery systems
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
A robust cell voltage monitoring system for analysis and diagnosis of fuel cell or battery systems
چکیده انگلیسی

Cell voltage monitoring (CVM) systems are essential for the operation of fuel cell stacks and some battery systems, in the field as well as in the laboratory, because they allow the diagnosis and correction of problems that would otherwise go unnoticed and cause impaired performance or even permanent damage. A robust, safe, and low-cost design for a CVM unit is presented, using electromechanical relays as multiplexing switches. Some examples from the application of the unit on the University of Delaware's fuel cell battery hybrid buses are presented, including its use in automatically correcting anode flooding and diagnosing air channel blockage.