کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1428492 1509173 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design and fabrication of an aptasensor for chloramphenicol based on energy transfer of CdTe quantum dots to graphene oxide sheet
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
پیش نمایش صفحه اول مقاله
Design and fabrication of an aptasensor for chloramphenicol based on energy transfer of CdTe quantum dots to graphene oxide sheet
چکیده انگلیسی


• Aptasensor based on aptamer–QDs and GO was developed for chloramphenicol sensing.
• The fluorescence of QDs–Apt was quenched through energy transfer from QDs to GO.
• Chloramphenicol was detected by recovering the quenched fluorescence.
• The limit of detection for chloramphenicol was calculated to be 98 pM.
• The proposed aptasensor showed high sensitivity, selectivity and precision.

Detection and quantification of chloramphenicol have played essential roles in the effort to minimize food safety risk.Herein, a sophisticated “turn on” aptasensor based on aptamer–CdTe quantum dots (Apt–QDs) and graphene oxide (GO) was developed for chloramphenicol sensing. In this assay, the fluorescence of CdTe QDs–Apt was efficiently quenched through energy transfer from QDs–Apt to GO, and chloramphenicol was detected by recovering the quenched fluorescence due to specific binding between aptamer and chloramphenicol.The results indicated that the addition of a CdTe QDs-labeled aptamer to a GO solution (250 μg/mL) led to a high quenching efficiency, yielding over 90% fluorescence quenching.Using a series of chloramphenicol concentrations (0.1 to 10 nM) aptasensor provides a limit of detection and limit of quantification at 98 pM and 987 pM, respectively. Linearity of response over chloramphenicol was demonstrated (r > 0.99).Furthermore, the GO-based aptasensor exhibited excellent selectivity toward chloramphenicol compared to other synthetic drugs with similar structures such as thiamphenicol, metronidazole and nitrofurantoin.Good reproducibility and precision (RSD 4.73%, n = 10) of the assay indicates the ability of the aptasensor for routine quantitative trace analysis of chloramphenicol.Our results suggested that the prepared aptasensor was also well qualified for the detection of chloramphenicol in milk with a limit of detection of 0.2 ppb.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Materials Science and Engineering: C - Volume 48, 1 March 2015, Pages 611–619
نویسندگان
, , , , ,