کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1430844 987211 2008 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation on corrosion behavior and haemocompatibility of phosphorus incorporated tetrahedral amorphous carbon films
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
پیش نمایش صفحه اول مقاله
Evaluation on corrosion behavior and haemocompatibility of phosphorus incorporated tetrahedral amorphous carbon films
چکیده انگلیسی

Phosphorus incorporated tetrahedral amorphous carbon (ta-C:P) films are deposited on biomedical titanium alloy (Ti6Al4V) by filtered cathodic vacuum arc technique. The structural properties of ta-C:P films are evaluated by X-ray photoelectron spectroscopy and Raman spectroscopy. Potentiodynamic polarization tests are employed to assess the corrosion performances of ta-C:P coated and uncoated Ti alloys in 0.89 wt.% NaCl solution. In vitro platelet adhesion measurements are performed to investigate the blood compatibility of ta-C:P films. Results indicate that phosphorus incorporation increases the corrosion resistance of ta-C films. More positive breakdown potential and lower corrosion current density than those of Ti alloy are observed for ta-C:P films. Lower platelet adhesion and activation demonstrate the enhanced haemocompatibility of Ti alloy coated with ta-C:P films. The improved interaction between ta-C:P films and biological environments is attributed to structural changes of the films after phosphorus introduction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Materials Science and Engineering: C - Volume 28, Issue 8, 1 December 2008, Pages 1408–1413
نویسندگان
, , , , ,