کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1469982 | 990313 | 2011 | 10 صفحه PDF | دانلود رایگان |

Heterogeneous corrosion of mild steel under sulphate reducing bacteria (SRB)-biofilm was characterised by wire beam electrode (WBE) technique and electrochemical impedance spectrum. The potential/current distributions of the WBE under SRB-biofilm showed that the potential maps could not indicate the localised corrosion of steels beneath biofilm due to the fact that all wire electrodes were short-circuited by the highly conductive sulphide precipitates embedded in SRB-biofilm. Instead, the galvanic current maps may give a good indication. The characteristic of super-capacitance (0.21 F/cm2) of SRB-biofilm was attributed to the huge specific surface area of conductive pore walls inside biofilm.
► Highly conductive SRB-biofilm can shield the potential differences of mild steel.
► Potential maps fail to indicate the localised corrosion of steel under SRB-biofilm.
► Galvanic current maps can detect the location of localised corrosion under biofilm.
► SRB-biofilm is super-capacitive due to the conductive sulphide micropores.
Journal: Corrosion Science - Volume 53, Issue 9, September 2011, Pages 2978–2987