کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1470153 | 990319 | 2010 | 11 صفحه PDF | دانلود رایگان |
Nickel-based alloy 625 was investigated by means of a conventional corrosion test (Streicher-test according to ASTM G28A [1]) and an electrochemical potentiokinetic reactivation test (according to ASTM G108 [1], with some modifications). Susceptibility to intergranular corrosion after various heat treatments was examined by using both test methods and the results were compared. Dependent on the type of heat treatment applied, both methods showed partially different results. Possibilities and limitations of replacing Streicher-test with EPR-test are pointed out and commentated. In conclusion, the EPR-test presents itself as a promising and quick investigation technique for detecting susceptibility to intergranular corrosion in nickel-based alloys.
Journal: Corrosion Science - Volume 52, Issue 5, May 2010, Pages 1582–1592