کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1471683 990357 2006 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Testing of high temperature reference electrodes for light water reactor applications
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد سرامیک و کامپوزیت
پیش نمایش صفحه اول مقاله
Testing of high temperature reference electrodes for light water reactor applications
چکیده انگلیسی

The main objective of the LIRES (light water reactor reference electrodes) project, supported by the EC within the EURATOM FP5, was to develop reference electrodes, which are robust enough to be used inside a light water reactor at temperatures up to 320 °C and pressures up to 120 bar. This contribution summarises the test of three types of reference electrodes developed within LIRES: (i) an external Ag/AgCl reference electrode from the NRI, Rez, Plc, (ii) a PtIr alloy hydrogen electrode from Studsvik Nuclear AB, and (iii) a Pd-hydride reference electrode—Pd(Pt) polarised active electrode pair—from the VTT Technical Research Centre of Finland. Our results are being compared, within a Round Robin test, with similar measurements of a number of laboratories to select the appropriate reference electrodes for long-term tasks, when the potential should be monitored for months under irradiating conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Corrosion Science - Volume 48, Issue 8, August 2006, Pages 1899–1911
نویسندگان
, , ,