کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1472060 990369 2007 21 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Continuous monitoring of aluminum corrosion process in deaerated water
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد سرامیک و کامپوزیت
پیش نمایش صفحه اول مقاله
Continuous monitoring of aluminum corrosion process in deaerated water
چکیده انگلیسی

A device was developed for the continuous measurement of the open circuit corrosion rate of aluminum in deaerated water from hydrogen pressure, resulted from the cathodic reaction. Corrosion rate of aluminum coated by the passive oxide film was examined with respect to the corrosion phenomena using this device. From the results, it was found that the corrosion rate was dependent not only on the deterioration of the film, but also on the formation of pits and of corrosion products on the film. Furthermore, the deterioration of the film was independent on the pH of the water. The pits were most probably formed by the evolution of hydrogen gas at the cathode underneath the film followed by the formation of Al(OH)4-.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Corrosion Science - Volume 49, Issue 6, June 2007, Pages 2581–2601
نویسندگان
, , , , ,