کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1472157 990372 2007 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
SKFM observation of SCC on SUS304 stainless steel
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد سرامیک و کامپوزیت
پیش نمایش صفحه اول مقاله
SKFM observation of SCC on SUS304 stainless steel
چکیده انگلیسی

We have developed a new SCC test device that enables the SKFM (super Kelvin force microscope) observation. By using this test device, SCC test was done at 343 K and 28% RH with attaching MgCl2 droplets. The crack tip deformation was observed by both KFM and SKFM. The results show that cracks initiated from the pit were usually found within half day. The negative potential parts were observed on both cracked parts and some of slip deformation parts and disappeared with time when the specimen was kept in the air. Discontinuous cracks were often found near the tip of the slip deformation part. These discontinuous cracks joined together and the amount of slip deformation increased with the progress of the crack. The negative potential part is considered to be the part where hydrogen exists. The movement of hydrogen generated by the cathodic reaction plays the important role to create the crack.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Corrosion Science - Volume 49, Issue 1, January 2007, Pages 120–129
نویسندگان
,