کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1576859 1514789 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Phenomenological description and temperature dependence of serrated flow in Ni–10Pd during high temperature instrumented microindentation
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد دانش مواد (عمومی)
پیش نمایش صفحه اول مقاله
Phenomenological description and temperature dependence of serrated flow in Ni–10Pd during high temperature instrumented microindentation
چکیده انگلیسی

Instrumented microindentation tests were carried out on a Ni–10Pd solid solution from 30 °C to 450 °C with a loading rate of 125 mN/s. When this sample was tested below 350 °C, the loading segment of the load–depth curves exhibited a smooth transition. In contrast, for tests conducted above 350 °C, the loading segment was initially smooth and then became serrated after reaching a critical load. Increase in testing temperature resulted in an earlier occurrence of serrated flow with a lower load threshold. With the intersections and transitions between the flat “A” segments and steep “B” segments individually defined, the depth and load increment associated with each segment were quantified and analyzed to phenomenologically describe the serrated flow behavior. By accounting for the dislocation reconfigurations and solute–dislocation interactions, a modified cavity expansion model was developed and used to elucidate the underlying physics.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Materials Science and Engineering: A - Volume 554, 30 September 2012, Pages 41–47
نویسندگان
, ,