X-ray computed tomography (CT) is used to explore the differences in a semi-batch bubble column operated at superficial gas velocities of Ug=3Ug=3, 10, and 18 cm/s. Air–water or air–water–cellulose fiber systems comprise the multiphase flow, and the bubble column has a 32.1 cm internal diameter. A CT image of a phantom object composed of several air-filled tubes immersed in water is used to identify several characteristic features of the X-ray CT system. CT images are then compared between air–water and air–water–cellulose fiber systems. When the fiber mass fraction is 0.1%, gas holdup is slightly higher than that of the air–water system in the column center and near the column wall. In 1.0% cellulose fiber slurries, gas holdup is lower than that of air–water results at all radial positions.
Journal: Chemical Engineering Science - Volume 60, Issue 22, November 2005, Pages 6124–6133