کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1682815 1518743 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
FTIR analysis of polyethylene terephthalate irradiated by MeV He+
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد سطوح، پوشش‌ها و فیلم‌ها
پیش نمایش صفحه اول مقاله
FTIR analysis of polyethylene terephthalate irradiated by MeV He+
چکیده انگلیسی

The degradation induced by MeV He+ ions onto polyethylene terephthalate (PET) is investigated as a function of fluence and electronic stopping power (dE/dx)e. Stack samples of four 3.6 μm PET films are irradiated by 3.5 MeV He+ under vacuum and room temperature at fluence ranging from 1013 to 1.5 × 1015 He+ cm−2. The entrance energies range from 3.5 MeV for the front film to 0.573 MeV for the rear one at the beginning of the irradiation and the corresponding mean (dE/dx)e lie for pristine PET between 158 and 264 keV/μm. A Fourier transform infrared spectroscopy (FTIR) analysis is undertaken. The different stack films present similar damages with magnitude increase as the fluence goes up. Moreover, higher is the electronic stopping power (dE/dx)e more important is the damage. The evolution of the normalized integrated absorbance A(ϕϕ)/A0 of the internal reference 1410 cm−1 band as a function of the fluence ϕϕ presents a complex behavior characterized by a two-exponential decay associated to low and high fluence range. The analysis reveals clearly that the A(ϕϕ)/A0 of the characteristic benzene ring 1577 cm−1 band remains steady till fluence around 3 × 1014 He+ cm−2 and then decreases smoothly as fluence increases. The band appearing at 1610 cm−1, assigned to mono substituted benzene, presents an integrated absorbance A(ϕϕ) which rises progressively and levels off beyond a critical fluence around 4 × 1014 He+ cm–2. The cross section of the creation of the monosubstituted benzene lies between 3 × 10−15 and 6 × 10−15 cm2 for (dE/dx)e = 158 and 264 keV/μm, respectively.Drastic loss of crystallinity is induced by the MeV He+ ion irradiation in the polymer. The amorphization is monitored by the evolution of the specific bands of the trans and gauche ethylene glycol residue conformations. A sudden drop in the integrated absorbance of the 1340 cm−1 band which characterizes the trans conformation is observed at fluence around 2 × 1014 He+ cm−2. On the other hand, a drastic increase is present in the integrated absorbance of the gauche conformation 1370 cm−1 band that pairs up with 1340 cm−1 band. This observation is a clear indication of the conversion of the trans ethylene glycol residue to gauche one under irradiation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms - Volume 274, 1 March 2012, Pages 70–77
نویسندگان
, , , , ,