Trace elements concentration in sediments of Orontes River using PIXE technique
چکیده انگلیسی

Proton induced X-ray emission (PIXE) has been used to measure trace elements in sediments of Orontes River. Measurements were carried out using a 2 MeV proton beam produced from of the 3 MV tandem accelerator. Sediment samples were collected from 11 sites covering the important potential pollution sources at the river. The accuracy of the experimental procedure was verified using a certified sediment reference material (IAEA-SL1) and was found to be less than 10%. The results have shown that Pb and As were within the natural levels. In contrast, high concentrations of other elements like Cr, Cu, Ni and Zn have been found at different sites and explained by local human and industrial activities.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms - Volume 269, Issue 16, 15 August 2011, Pages 1818–1821