کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1728815 1521148 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biological shield design for a 10 MeV Rhodotron
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Biological shield design for a 10 MeV Rhodotron
چکیده انگلیسی

Radiation field of the Rhodotron-TT200 electron accelerator is determined in this study. Regarding the interactions of electron with matter, the produced radiations and their attenuation to the permitted level (i.e. 0.01 mrem/h) are evaluated and calculated. For this purpose analytical calculations are applied to determine the biological shield material and thickness. In order to make sure of results accuracy, Rhodotron accelerator and its shielding are simulated using MCNPX code and the results of analytical calculations and MCNPX code are compared with the experimental ones.


► We evaluate the produced radiations of the Rhodotron-TT200 and their attenuation to the permitted level.
► We apply analytical calculations to determine the shield material and thickness.
► We simulate the Rhodotron accelerator and its shielding using MCNPX code to make sure of results accuracy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Annals of Nuclear Energy - Volume 50, December 2012, Pages 111–116