Using a counting system with plastic scintillation detector, beta linear and mass attenuation coefficients were determined for bakelite, Al, Fe and plexiglass absorbers by means of timing method. To show the accuracy and reliability of the obtained results through this method, the coefficients were also found via conventional energy method. Obtained beta attenuation coefficients from both methods were compared with each other and the literature values. Beta attenuation coefficients obtained through timing method were found to be compatible with the values obtained from conventional energy method and the literature.
► Beta attenuation coefficients of absorber materials were found in this study.
► For this process, a new method (timing method) was suggested.
► The obtained beta attenuation coefficients were compatible with the results from the traditional one.
► The timing method can be used to determine beta attenuation coefficient.
Journal: Annals of Nuclear Energy - Volume 41, March 2012, Pages 115–118