کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1729039 | 1521155 | 2012 | 5 صفحه PDF | دانلود رایگان |
![عکس صفحه اول مقاله: Photon attenuation coefficients of concrete including marble aggregates Photon attenuation coefficients of concrete including marble aggregates](/preview/png/1729039.png)
The linear attenuation coefficients (μ, cm−1) for concrete having marble aggregates in different concentrations have been investigated. The marble concentrations investigated in the work were 0%, 5%, 10%, 15%, 20% and 25% in concrete. The measurements were performed using a gamma spectrometer that contains a NaI(Tl) detector and Multi-Channel-Analyser (MCA) connected to a PC. Three different gamma rays energies have been used at 662, 1173 and 1332 keV from 137Cs and 60Co sources respectively. The measured results were compared with the calculation obtained using computer code of XCOM for 1 keV–1 GeV gamma energies.
► Linear attenuation coefficients measurement of marble concrete.
► Radiation shielding properties of concrete.
► Comparison of measurement with the calculations.
Journal: Annals of Nuclear Energy - Volume 43, May 2012, Pages 56–60