کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1729283 1521165 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of calculated and measured reaction rates obtained through foil activation in the subcritical dual spectrum facility YALINA-Booster
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Comparison of calculated and measured reaction rates obtained through foil activation in the subcritical dual spectrum facility YALINA-Booster
چکیده انگلیسی
► Reaction rates were measured by the foil activation technique in the subcritical core of YALINA-Booster. ► The experimental results are compared with MCNP calculations using ENDFB-6.8, JEFF-3.1.1 and CENDL-3.1 libraries. ► A discrepancy of the C/E values for high-threshold reactions reaches up to 20% for all three libraries. ► An inaccurate cross section of 115In(n, γ)116Inm reaction is identified in CENDL-3.1. ► The results indicate a difficulty of precise reaction rate calculations by MCNP in subcritical systems using the common neutron cross section libraries.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Annals of Nuclear Energy - Volume 38, Issue 6, June 2011, Pages 1412-1417