کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1729820 1521177 2010 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of the subcriticality level using the 252Cf source-detector method
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Determination of the subcriticality level using the 252Cf source-detector method
چکیده انگلیسی
Before the actual measurements took place, a suitable data acquisition system was realized in order to process the signals and compute the auto and cross power spectral densities. The measurements were then performed in the VENUS reactor, using the 252Cf source-detector and two BF3 neutron detectors. The multiplication factor was determined using the Cf source method and compared with measurements using other methods and with computational results (Monte Carlo simulations). The Cf method was benchmarked at a UOX core to other experimental methods that used the critical state as reference and to calculations. Afterwards, the Cf source technique was analyzed in a MOX core to study the possible impact of a significant intrinsic source on the results. This benchmarking gives the possibility to validate the Cf method as a reliable technique for the measurement of subcritical levels in steady state and for cores with an intrinsic source like MOX or burnt fuel cores.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Annals of Nuclear Energy - Volume 37, Issue 5, May 2010, Pages 740-752
نویسندگان
, , , , , , ,