کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1732884 1521488 2013 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An experimental exergetic comparison of four different heat pump systems working at same conditions: As air to air, air to water, water to water and water to air
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
An experimental exergetic comparison of four different heat pump systems working at same conditions: As air to air, air to water, water to water and water to air
چکیده انگلیسی


• A multifunctional heat pump can be run in four modes is founded.
• COP, exergy efficiency and exergy destruction of heat pumps were evaluated, compared and discussed.
• Comparison was made regarding temperature and mass flow rate changes of the evaporator fluid.
• The best type is water to air according to COP and exergy efficiency and water to water according to exergy destruction.

In this study, we designed a multifunctional heat pump system using just one scroll compressor and which can be run in four different modes, namely air to air, air to water, water to water and water to air, in order to make an experimental energetic and exergetic performance comparison. Experimental system consists of two condensers and two evaporators and uses R22 as working fluid. One of the evaporators and condensers uses water and the others use air as heat source/sink. Heating capacities of four heat pump types are equal to each other. It is realized by adjusting the mass flow rate and temperature level of external fluid of condenser. Results show that the heat pump unit which has the maximum COP (coefficient of performance) value is water to air type with 3.94 and followed by water to water type with 3.73, air to air type with 3.54 and air to water type with 3.40. Ranking of four heat pump types with respect to their mean exergy efficiency is as follows; water to air type with 30.23%, air to air type with 30.22%, air to water type with 24.77% and water to water type with 24.01%. Exergy destruction rates of the systems were investigated in this study and the results revealed that the heat pump type which has the maximum exergy destruction is air to air type with 2.93 kW. The second highest one is air to water type with 2.84 kW. The third highest one is water to air type with 2.64 kW and last one is water to water type with 2.55 kW. It is understood that the temperature of the evaporator external fluid affects the exergetic efficiency of the system more than the mass flow rate. In contrast to the previous, the dominant parameter which has more important effect on the exergy destruction of the heat pump unit is the mass flow rate of evaporator external fluid.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy - Volume 58, 1 September 2013, Pages 210–219
نویسندگان
, , , ,