کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1734929 1016168 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sensitivity analysis of steam power plant-binary cycle
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Sensitivity analysis of steam power plant-binary cycle
چکیده انگلیسی
This paper analyses a steam power - two-stage binary cycle plant (SPP-2BCP), in which low temperature waste heat from a conventional steam power plant can be efficiently utilized to generate electricity by installing a bottoming binary cycle. The result from a previous calculation on the installation of binary cycle technology on a Steam Power Plant (SPP) with n-Pentane working fluid indicates an increase in plant efficiency of about 9%. The purpose of this study is to analyze the sensitivity of performance of the binary cycle system against variations in the SPP operational load and the condenser's cooling water temperature. The calculation is conducted on SPP load variations of 25%, 50%, 75% and 100%, inlet turbine pressure variations of 5 bar-30 bar, and inlet turbine temperature variations of 125 °C up to 235 °C. Each of these is also analyzed with ambient cooling water temperatures of 30 °C-37 °C. The results of the analysis indicate that the performance of this binary cycle SPP degrades slightly with SPP load, turbine inlet temperature, and turbine inlet pressure variations and with cooling water variations.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy - Volume 35, Issue 9, September 2010, Pages 3578-3586
نویسندگان
, , , , , ,