کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1735220 | 1016174 | 2010 | 10 صفحه PDF | دانلود رایگان |

This paper presents the steady-state behavior of a series compensated (short-shunt) self-excited six-phase induction generator (SPSEIG) configured to operate as stand-alone electric energy source in conjunction with a hydro power plant. A purely experimental treatment is provided with the emphasis placed on operating regimes that illustrate the advantages of using SPSEIG. In particular, it is shown that the SPSEIG can operate with a single three-phase capacitor bank, so that the loss of excitation or fault at one winding does not lead to the system shutdown. The generator can also supply two separate three-phase loads, which represent an additional advantage. Experimental results include loading transients with independent three-phase resistive and resistive–inductive load at each of the two three-phase winding sets, and measured steady-state characteristics for various load and/or capacitor bank configurations. Practical results for long-shunt configuration are also given for comparative performance evaluation of series compensated SPSEIG.
Journal: Energy - Volume 35, Issue 1, January 2010, Pages 288–297