کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1735392 1016180 2009 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of air gap on the performance of building-integrated photovoltaics
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Effect of air gap on the performance of building-integrated photovoltaics
چکیده انگلیسی

Ventilation of photovoltaic (PV) modules installed over or beside a building envelope can reduce the module temperature and increase the electrical conversion efficiency. A computational fluid dynamics (CFD) method has been used to assess the effect of the size of air gap between PV modules and the building envelope on the PV performance in terms of cell temperature for a range of roof pitches and panel lengths and to determine the minimum air gap that is required to minimise PV overheating. It has been found that the mean PV temperature and the maximum PV temperature associated with hot spots decrease with the increase in pitch angle and air gap. The mean PV temperature also decreases with increasing panel length for air gaps greater than or equal to 0.08 m whereas the maximum PV temperature generally increases with panel length. To reduce possible overheating of PV modules and hot spots near the top of modules requires a minimum air gap of 0.12–0.15 m for multiple module installation and 0.14–0.16 m for single module installation depending on roof pitches.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy - Volume 34, Issue 7, July 2009, Pages 913–921
نویسندگان
,