کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1823990 1645430 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Compton imaging with thick Si and CZT detectors
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Compton imaging with thick Si and CZT detectors
چکیده انگلیسی

A Compton imaging telescope has been constructed using a 0.2 cm thick Silicon (Si) detector of active area 9.0×9.0 cm2 and a pixelated Cadmium Zinc Telluride (CZT) detector of dimensions 2.0×2.0×0.5 cm3. The Si detector is double sided with 64 strips per side in two orthogonal directions. The CZT detector has 64 pixels of pitch 0.25 cm. We used several ASICs (32 channel) to read out both detectors. A 137Cs source was used in the study. The energy deposited in the Si and CZT detectors and the points of interaction of the γ-ray in both detectors were read out. We varied the position of the source as well as the vertical separation between the Si and CZT detectors and measured the angular resolution of the source image for the different configurations. The best angular resolution (1σ) was 2.4°. Monte Carlo simulations were run for similar detector configurations and agree with the experimental results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 682, 1 August 2012, Pages 79–84
نویسندگان
, , , , , ,