کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1825797 1526467 2010 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Photoemission experiments of a large area scandate dispenser cathode
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Photoemission experiments of a large area scandate dispenser cathode
چکیده انگلیسی

A 100-mm-diameter scandate dispenser cathode was tested as a photocathode with a 10 ns Nd:YAG laser (266 nm) on an injector test stand for linear induction accelerators. This thermionic dispenser cathode worked at temperatures ranging from room temperature to 930 °C (below or near the thermionic emission threshold) while the vacuum was better than 4×10−7 Torr. The laser pulse was synchronized with a 120 ns diode voltage pulse stably and they were in single pulse mode. Emission currents were measured by a Faraday cup. The maximum peak current collected at the anode was about 100 A. The maximum quantum efficiency measured at low laser power was 2.4×10−4. Poisoning effect due to residual gas was obvious and uninterrupted heating was needed to keep cathode’s emission capability. The cathode was exposed to air one time between experiments and recovered after being reconditioned. Photoemission uniformity of the cathode was also explored by changing the laser spot’s position.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 621, Issues 1–3, 1–21 September 2010, Pages 79–82
نویسندگان
, , , , , , , , , ,