Optimization of a moderator-neutron guide system for diffractometers of beam line 7A of the IBR-2M reactor
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Optimization of a moderator-neutron guide system for diffractometers of beam line 7A of the IBR-2M reactor
چکیده انگلیسی

Neutron guides are widely used to transport the neutrons from the moderator to the sample. Due to the constructive features of the ring corridor of the fast pulsed reactor IBR-2, the minimal distance between the moderator and the guide entrance is around 6 m. The main goal of the paper is to optimize the neutron optical system between the moderator and the entrance of the new neutron guides. Using Monte Carlo simulations we calculate the possible best gain of the neutron flux density at the guide exit. After the described optimization process, the optimal system is obtained. The recommendations for construction of the new beam line are provided too. Similar technique and the proposed system could be easily adapted for another similar beam line at the neutron sources.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 608, Issue 3, 21 September 2009, Pages 447–453