Design, optimization and performance of source and detector collimators for gamma-ray scanning of a lab-scale distillation column
ترجمه فارسی عنوان
طراحی، بهینه سازی و کارآیی کالیاتورهای منبع و آشکارساز برای اسکن کردن گاما یک ستون تقطیر در مقیاس آزمایشگاهی
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی


• Design and optimization of the source and detector collimators.
• MCNP4C simulations of collimators for gamma scan of distillation columns.
• Optimization of the pinhole and panoramic collimators for source.
• Optimization of pinhole and semi-quartic collimators for detector.
• Investigation the effect of the designed collimators on the density profiles.

When using source and detector collimators for gamma ray column scanning, it is important to obtain an acceptable density profile quality. This paper consists of two main works. The first is devoted to describing the designs used to optimize the source and detector collimators for a lab-scale distillation column, and the second is devoted to investigating the effect of designed collimators on the quality of the density profiles obtained using the gamma scanning technique. Simulations using the MCNP4C Monte Carlo code were performed to model the collimators and obtain the density profiles. The source and detector collimator designs were developed for a cylindrical volume source with the energy of 0.662 MeV and 1 in.×1 in. NaI, respectively. The pinhole and panoramic collimator designs and the pinhole and quartic collimator designs were considered for the source and the detector, respectively. The source container, with an opening angle of 60°, has the capability of substituting the collimator for high resolution, general and high sensitivity purposes. The pinhole collimator parameters for the source that were obtained were generally quite coarse and were 1.2 cm in diameter and 4 cm in length. Additionally, the detector pinhole collimator thickness and length obtained were 4 cm and 5 cm, respectively. Using the semi-quartic collimator for the detector, the weight of required lead was reduced by over 33% compared with the pinhole collimator.The simulation results of the column scanning in abnormal operation condition have been validated by experimental measurement results. The obtained results from scans demonstrated that the optimized panoramic source collimator and semi-quartic detector collimator in this study could help us to obtain an acceptable density profile quality in total count approach.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 99, May 2015, Pages 25–34
نویسندگان
, ,