کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1875897 1532109 2014 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Project for the development of the linac based NCT facility in University of Tsukuba
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Project for the development of the linac based NCT facility in University of Tsukuba
چکیده انگلیسی


• A project team headed by University of Tsukuba launched a development of new accelerator based BNCT facility.
• The project adopted an 8 MeV RFQ+DTL type linac as proton accelerator.
• The linac tube is completed and installed in BNCT facility at Tokai village.
• Neutron generator device with beryllium target is being also designed and several medical devices as treatment planning system, patient positioning device are being also developed.
• We are now developing a new multi-modal Monte-Carlo treatment planning system based on JCDS.

A project team headed by University of Tsukuba launched the development of a new accelerator based BNCT facility. In the project, we have adopted Radio-Frequency Quadrupole (RFQ)+Drift Tube Linac (DTL) type linac as proton accelerators. Proton energy generated from the linac was set to 8 MeV and average current was 10 mA. The linac tube has been constructed by Mitsubishi Heavy Industry Co. For neutron generator device, beryllium is selected as neutron target material; high intensity neutrons are generated by the reaction with beryllium and the 80 kW proton beam.Our team chose beryllium as the neutron target material. At present beryllium target system is being designed with Monte-Carlo estimations and heat analysis with ANSYS. The neutron generator consists of moderator, collimator and shielding. It is being designed together with the beryllium target system. We also acquired a building in Tokai village; the building has been renovated for use as BNCT treatment facility. It is noteworthy that the linac tube had been installed in the facility in September 2012.In BNCT procedure, several medical devices are required for BNCT treatment such as treatment planning system, patient positioning device and radiation monitors. Thus these are being developed together with the linac based neutron source. For treatment planning system, we are now developing a new multi-modal Monte-Carlo treatment planning system based on JCDS. The system allows us to perform dose estimation for BNCT as well as particle radiotherapy and X-ray therapy. And the patient positioning device can navigate a patient to irradiation position quickly and properly. Furthermore the device is able to monitor movement of the patient׳s position during irradiation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 88, June 2014, Pages 211–215
نویسندگان
, , , , , , , , , ,