کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1877788 1042239 2011 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR
چکیده انگلیسی

This paper aims to evaluate the effective dose as well as equivalent doses of several organs of an adult hermaphrodite mathematical phantom according to the definition of ICRP Publication 60 for BNCT treatments of brain tumors in the epithermal neutron beam at THOR. The MCNP5 Monte Carlo code was used for the calculation of the average absorbed dose of each organ. The effective doses for a typical brain tumor treatment with a tumor treatment dose of 20 Gy-eq were evaluated to be 0.59 and 0.35 Sv for the LLAT and TOP irradiation geometries, respectively. In addition to the stochastic effect, it was found that it is also likely to produce deterministic effects, such as cataracts and depression of haematopoiesis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 69, Issue 12, December 2011, Pages 1850–1853
نویسندگان
, , , , ,