Tests of nuclear half-lives as a function of the host medium and temperature: Refutation of recent claims
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Tests of nuclear half-lives as a function of the host medium and temperature: Refutation of recent claims
چکیده انگلیسی

When radioactive isotopes that decay by α, β−, β+ and electron-capture transitions are placed in a conducting host material, it has recently been claimed that their half-lives show a significant dependence on temperature—up to a 6% difference between room temperature and 12 K. We have refuted two of these claims by measuring: (1) the β− decay of 198Au in gold, for which we find the half life to be the same within 0.04% between room temperature and 19 K; and (2) the electron-capture decay of 97Ru in ruthenium, for which we find any half-life difference to be <0.1%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 68, Issues 7–8, July–August 2010, Pages 1550–1554