کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1878744 1532115 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simulation and measurement of characteristics of MICROMEGAS gaseous detectors
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Simulation and measurement of characteristics of MICROMEGAS gaseous detectors
چکیده انگلیسی


• We fabricated two MICROMEGAS detectors and studied their characteristics.
• GARFIELD simulations were performed and the results were compared with the experiments.
• Dependence of the amplification on the gas mixture and the voltage was studied.
• The energy resolution of the detector is found to be 16–19% at 5.9 keV and 9–11% at 22 keV.

MICROMEGAS detectors have been developed for the detection and tracking of charged and neutral particles. The control parameters of MICROMEGAS include materials, the type of gases, the mixing ratio of gases and the geometry. Simulations of MICROMEGAS are conducted to optimize the characteristics and performance with respect to the nature of the gas mixture, applied voltages of drift and amplification regions. Quantities such as the equi-potential lines, electron drift lines, and avalanche process of electrons and ions are calculated. Two MICROMEGAS detectors are built and characterized by using standard X-ray sources. The voltage gains are measured against the applied voltage range for different gas pressures and are compared with our simulation results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 81, November 2013, Pages 156–161
نویسندگان
, , , , , , , ,