کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1878908 | 1532085 | 2016 | 5 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Modelling of dynamic experiments in MCNP5 environment
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
تشعشع
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The design of radiation measurement systems includes a modelling phase which ascertains the best 3D geometry for a projected gauge. To simulate measured counts by a detector, the widely-used rigorous phenomenological model is used. However, this model does not consider possible source or/and detector movement during a measurement interval. Therefore, the phenomenological model has been successfully modified in order to consider such a displacement during the time sampling interval in dynamic experiments. To validate the proposed model, a simple radiation system was accurately implemented in the MCNP5 code. The experiments confirmed the accuracy of the proposed model.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 112, June 2016, Pages 136-140
Journal: Applied Radiation and Isotopes - Volume 112, June 2016, Pages 136-140
نویسندگان
Volodymyr Mosorov, Marcin Zych, Robert Hanus, Leszek Petryka,