کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1883172 1533544 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monte Carlo modelling and real-time dosemeter measurements of dose rate distribution at a 60Co industrial irradiation plant
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Monte Carlo modelling and real-time dosemeter measurements of dose rate distribution at a 60Co industrial irradiation plant
چکیده انگلیسی

The dose rate distribution in a MDS Nordion JS7500 60Co industrial irradiation plant has been calculated using the egspp Monte Carlo code. This code is a development of the established EGSnrc code developed and distributed by National Research Council of Canada.The coding method is described and absolute dose rates given for each of the dwell positions in the path through the irradiator. These calculated dose rates have been compared with measurements made using a radiation resistant electronic dosimetry system. In addition, the integral dose derived from calculated and measured dose rates has been compared to the value obtained using chemical dosimeters.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Physics and Chemistry - Volume 78, Issues 7–8, July–August 2009, Pages 453–456
نویسندگان
, , ,