کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1884452 1043343 2010 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of cable ageing
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Comparison of cable ageing
چکیده انگلیسی

Two cable types, which currently are used in nuclear power plants (NPP) and which are composed by jacket/insulation materials, i.e. PVC/PVC and PVC/PE, were exposed to accelerated ageing conditions, in order to simulate their behavior after 10 years in service. The cables were aged under two different test conditions:(a)With relatively high accelerating ageing speed:Radiation ageing was carried out at room temperature at a dose rate of 2900 Gy/h, followed by thermal ageing at 100 °C. This accelerated ageing condition was fairly fast, but still in compliance with the standards.(b)With moderate ageing speed:The radiation and thermal ageing was performed simultaneously (superimposed) at a dose rate of 2.7–3.7Gy/h and a temperature of 68–70 °C. Such a test condition seems to be very close to the radiation and temperature impact onto the cables in the real NPP service.Finally, mechanical properties were measured to characterize the ageing status of the cables.The purpose of this study was to compare degradation effects, derived from both ageing methods, and to demonstrate that results obtained from high values of accelerating parameters and from fast ageing simulation can be very different from reality. The observed results corroborated this assumption.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Physics and Chemistry - Volume 79, Issue 3, March 2010, Pages 371–374
نویسندگان
, ,