کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1884730 1043362 2007 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Formyl violet cyanide liquid dosimetry system
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Formyl violet cyanide liquid dosimetry system
چکیده انگلیسی

Aqueous solutions of formyl violet cyanide (FV-CN) have been investigated for potential use in radiation dosimetry using both absorption and fluorescence evaluation. A radiation-induced absorption band peaking at 590 nm was observed and this wavelength was chosen for fluorimetric experiments, where a radiation-induced emission band develops at 600 nm. The useful dose range of the solution was found to be 400–4000 Gy depending on the FV-CN concentration and the evaluation method. The pre- and post-irradiation stabilities of the solutions were found to be satisfactory.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Physics and Chemistry - Volume 76, Issue 7, July 2007, Pages 1218–1221