کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1886140 1533527 2014 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of a radioxenon measurement system and its application in monitoring Fukushima nuclear accident
ترجمه فارسی عنوان
توسعه یک سیستم سنجش رادیو اکسنون و کاربرد آن در نظارت بر حوادث هسته ای فوکوشیما
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی
An HPGe gamma-ray spectrometry system for radioxenon isotopes detection has been developed. The system was comprised of two low-energy planar HPGe detectors that were horizontally and oppositely placed, and a gas source cell made of carbon fiber in both sides was used. The spectra obtained simultaneously by the two HPGe detectors were analyzed by summing spectrum method. After the radioactive concentration of 133Xe was determined with three internal gas proportional counters, the efficiency of 81 keV gamma-ray for 133Xe was calibrated to be 0.50 (1), and the Minimum Detectable Activity (MDA) for 133Xe detection was determined to be 10 mBq during 1 day measurement time. Finally, the system was applied in atmospheric 133Xe monitoring at Xi'an of China after the Fukushima nuclear accident.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Physics and Chemistry - Volume 97, April 2014, Pages 85-89
نویسندگان
, , , , , , , , ,